Buckleys: Calibration Kit for UCP1A/UCP1B CP Probes
Buckleys: Calibration Kit for UCP1A/UCP1B CP Probes
Survey Equipment

Buckleys: Calibration Kit for UCP1A/UCP1B CP Probes

Availability:

The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys Contact and Proximity Probes so that ‘in-house’ verification certificates can be issued.

Providing the readings are correct, the silver/silver chloride screw-in half cell should be checked by using K-SAT Reference Cells in a standard salt water solution.

To confirm the readings, three cells should be used and the sea water corrosion test mixture should be made up to a 3% solution.

Kit comprises:

  • 3 x screw-on K-SAT reference electrode cells
  • Sea water corrosion test mixture
  • 3 x Adaptor leads
  • 1 x zinc test block
  • Full instructions for ‘in-house’ verification

Features

Easy to use.

All kit parts can be replaced individually.

Full instructions included.

Specifications

Electrical connection: screw fit

Output: +196mV @ 25°C vs SHE

Accuracy: ±10mV @ 25°C vs SHE

Temperature coeff: -0.64mV per/°C

Temperature range: 0 – 40 °C

Applications

Used for checking accuracy of readings and calibrating the equipment used in testing conditions.

Product Enquiry

Case Studies